fbpx

Compact P

Specifications & Technical Data

The Compact P is a combined ventilation and heating system that provides your house with ventilation, heat recovery and production of domestic hot water (DHW).

The Compact P ensures a daily air exchange with the removal of dust particles, smells and excess humidity in exchange for a pleasant and healthy indoor climate. When it is hotter inside than outside the house, a built-in bypass makes sure to let cool air directly into the house.If you want a total solution that covers central heating of the house as well, you should choose a Compact P solution with an outdoor air or ground source heat pump. Compact P is, as only one out of a few compact systems in the world, passive house certified due to its high efficiency. The certification means that the Compact P is certified for passive housing without any additional documentation ever being needed. 

 

ECODESIGN

Consumer profile, water heater L (large)
Energy efficiency class A
Energy efficiency for water heating – average climate 94 %
Annual electricity consumption – average climate 1081 kWh/annum
Temperature settings on the thermostat 10 – 65 °C
Sound power level LWA 57 dB(A)
The water heater can function outside peak load periods (Smart-grid) No
Guidelines for assembly, installation and maintenance See installation instructions
Energy efficiency for water heating – cold climate 94 %
Energy efficiency for water heating – warm climate 94 %
Annual electricity production – cold climate 1081 kWh/annum
Annual electricity consumption – warm climate 1081 kWh/annum

TECHNICAL DATA

Compact P is an energy-efficient total indoor climate solution for all types of low-energy buildings, single-family homes, flats and small office areas in commercial leases with a ventilation requirement of up to 275 m³/h.

Compact P recovers the energy from the extracted air using a highly efficient counter flow heat exchanger. The remaining energy that is not utilised by the counter flow heat exchanger is used by the heat pump to produce hot water, and to further heat the supply air.

The heat pump has a reversible cooling circuit, which means that, in the summer, the unit can cool the supply air by up to 10 °C. Due to the low air exchange, the cooling does not function as an air conditioning system. On cooling, the supply air is dehumidified, which gives a more pleasant indoor climate than is possible with an ordinary ventilation unit without a heat pump.

Compact P is also offered in a Polar version with a built-in preheating element to frost proof the counterflow heat exchanger.

Dimensions (WxDxH) 900 x 610 x 2,065 mm
Weight 202 kg
Plate type casing Aluzinc steel plate, white powder coating RAL9016
Heat exchanger type Polystyrene counterflow heat exchanger
Fan type EC, constant rotation
Filter class Standard G4
Duct connections Ø 160 mm
Condensate drain PVC, Ø 20×1.5 mm
External leakage < 1.4% (*1)
Internal leakage < 1.1% (*2)
Supply voltage 230 V (±10 %), 50/60 HZ
Max. input/power 2.2 kW/ 9.6 A (*3) // 3.4 kW/14.8 A (*4)
Tightness class IP31
Standby power 3 W
Ambient temperature -20/+40 °C

Ecodesign/ERP data

Fan data
Motordata (optimalt driftspunkt)
* 1    At ± 250 Pa and 265 m3/h according EN 308/EN 13141-7.
* 2    At ± 100 Pa and 265 m3/h according EN 308/EN 13141-7.
* 3    Input without heating element (accessory).
* 4    Input Compact Polar
Connections
1: Fresh air
2: Supply air
3: Extract air
4: Discharge air

AUTOMATION

The CTS602 control is an advanced control with many setting options. The control is delivered from the factory with a basic setting that can be adapted to the operational wishes and requirements, in order to achieve optimal operation and utilization of the unit.

The HMI Touch panel provides a good overview of the unit’s current operation, and has a menu structure that is easy to navigate for both user and installer. 

External communication
The CTS602 control has an open Modbus RS485 protocol that can be used to communicate with via external CTS systems. The Modbus connection is used e.g. for Schneider’s IHC or KNX system.

Functional overview CT602 control panel
CLICK TO VIEW
Function overview   +Standard
-Accessories
Filter guard The time-controlled filter guard notifies you when it is time to change the filter. Can be set between 30 and 180 days. +
Operating mode Can be set to run Auto according to set values ​​or set to run in heating or cooling mode. +
Stepless regulation The four ventilation stages can be set steplessly 20-100%, with different values ​​for supply air and extract air. +
Moisture management Built-in humidity control can be set to run high ventilation mode when there is high humidity (when you are in the shower) and low ventilation mode if the humidity in the home becomes too low. +
Active cooling The unit can be set to cool the supply air in the summer if needed. When the heat pump cools, the heat is deposited in the hot water tank, so that you get “free” hot domestic water when the unit is in cooling mode. +
Low outdoor temperature It is possible to lower the ventilation when the outside temperature is low, to avoid that the humidity inside becomes too low. +
CO2 management It is possible to control the ventilation level according to the home’s CO2 level.
Temperature settings The temperature settings are used by the controller to regulate the operation of the entire system. +
Frost protection The control has an automatic function for defrosting the heat exchanger if ice should form in it. +
Frost protection Polar The Polar model has a built-in anti-freeze pre-heater to protect the counter-flow heat exchanger so that it does not get ice. +
Frost protection EHD The control can control an EHD damper, which is used if the outside air comes via a roof hood. +
Hot domestic water Compact P produces the hot domestic water via the air/air heat pump in the ventilation part. +
Pause domestic hot water It is possible to pause hot water production if, for example, for a period not at home. In this way, energy is saved. +
Antifreeze hot water To protect the hot water tank, it is equipped with a frost protection function. +
Electricity supplement hot water

If the demand for hot water is so great during periods that the heat pump cannot keep up, an electric supplement can be switched on to help heat the hot domestic water.

+
Scalding protection The control has a built-in scalding protection, which ensures that the hot domestic water does not become too hot and could scald the users. +
Anti-Legionella The control has an Anti-Legionella treatment of the hot domestic water, which can be activated manually or automatically. +
Anode Electronically monitored anode. Notifies when it’s time to replace it, extending the life of the hot water tank.  
SHW preheating tank An additional hot water tank SHW can be connected to the GEO geothermal heat pump and preheat the hot domestic water to 45 ºC before it enters the Compact P hot water tank. +
Hot domestic water If the Compact P is ordered with a solar coil, the GEO ground source heat pump can be connected to the Compact P hot water tank and help produce the hot domestic water. A good solution if there is a large need for domestic hot water and there is no space for a SHW container. +
Weekly schedule A weekly plan can be made with different settings depending on the use of the home. +
Smart Grid Compact P GEO is approved for Smart Grid solutions, where the electricity company determines the electricity consumption and thus the operating costs. +
User selection 1 Used if you want to override the unit’s operation via a potential-free signal. Used e.g. if an extractor hood is connected to the system. +
User choice 2 Used as user selection 1, but at the same time has an output signal that can be used e.g. to control a damper. +
Event log Logs events in the control as well as error messages and warnings. +
Read out data All current values ​​in the plant’s operation can be read out. Most often used for troubleshooting. +
Emergency stop ventilation You must not switch off the ventilation, as this can cause damage to the unit, duct system and, in the worst case, the home. But it may be necessary to briefly switch off the ventilation, e.g. due to an emergency notification. +

Further information about all the functions can be found in the unit’s Software and Assembly instructions.