Compact P Air 9
Specifications & Technical Data
The Compact P Air9 has the same functions, benefits and options as the Compact P but can further be used to exploit outdoor air to heat the home.
The system is equipped with an outside air heat pump, Air9 Compact, which, in contrast to the system itself, is set up outside. The heat pump absorbs the energy in the outside air and coverts this energy into heat that is used to heat water in your central heating system, which is then pumped to the radiators or underfloor heating in your home.
The Compact P Air9 solution can reduce your heating bill by up to 50%. For each kW power used by the outside air heat pump, you get up to four times as much heat in return.

ECODESIGN
Model | AIR 9 |
Air-to-water heat pump | Yes |
Water-to-water heat pump | No |
Brine-to-water heat pump | No |
Low-temperature heat pump | Yes |
Equipped with a supplementary heater | Yes |
Heat pump combination heater | No |
Temperature control | |
Model | CTS700 |
Class | 2 |
Contribution to seasonal space heating energy efficiency | 2% |

Item | Symbol | Value | Unit | Item | Symbol | Value | Unit | |
Rated heat output (*) | Prated | 5,21 | kW | Seasonal space heating energy efficiency |
ŋs | 206 | % | |
*Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature of Tj | Declared capacity for heating for part load at indoor temperature 20 °C and outdoor temperature of Tj | |||||||
Tj = -7 °C | Pdh | 4,79 | kW | Tj = -7 °C | COPd | 3,20 | ||
Tj = +2 °C | Pdh | 2,88 | kW | Tj = +2 °C | COPd | 4,95 | ||
Tj = +7 °C | Pdh | 1,90 | kW | Tj = +7 °C | COPd | 6,53 | ||
Tj = +12 °C | Pdh | 2,12 | kW | Tj = +12 °C | COPd | 9,69 | ||
Tj = bivalent temperature | Pdh | 5,21 | kW | Tj = bivalent temperature | COPd | 2,83 | ||
Tj = operation limit temperature | Pdh | 0 | Tj = operation limit temperature | COPd | 0 | |||
For air-water-heating pumps Tj = -15 °C (if TOL < -20 °C) | Pdh | For air-water-heating pumps Tj = -15 °C (if TOL < -20 °C) | COPd | |||||
Bivalent temperature | Tbiv | -10 | For air-to-water heat pumps: Operation limit temperature |
-22 | °C | |||
Cycling interval capacity for heating | Pcych | Cycling interval efficiency | ||||||
Degradation co-efficient | Cdh | 0,94-0,99 | Heating water operating limit temperature |
WTOL | 45 | °C | ||
Power consumption in modes other than active mode | Supplementary heater | |||||||
Off mode | POFF | 0,01 | Rated heat output | Psup | 6 | kW | ||
Thermostat off-mode | PTO | 0,005 | ||||||
Standby mode | PSB | 0,01 | Type of energy input | Electrical | ||||
Crankcase heater mode | PCK | 0 | ||||||
Other items | ||||||||
Capacity control | Variabel kompressor Variabel indendørs vandflow | For air-to-water heat pumps: Rated air flow rate, outdoors |
3000 | m3/h | ||||
Variabel indendørs temperatur regulering | For water-/ brine-water heat pumps: Rated brine or water flow rate, outdoor heat exchanger | m3/h | ||||||
Sound power level, outdoors | LWA | 46 | dB | |||||
Emissions of nitrogen oxides | QHE | 1464 | kWh |
TECHNICAL DATA
The solution consists of an integrated interior section in Compact P, as well as an exterior section that is easy to connect.
AIR 9 is delivered with a reversible heat pump, which also makes the unit capable of cooling.
AIR 9 is very silent and can be placed without disturbing it surroundings. During summer, when only hot sanitary water is needed, the fan is limited, reducing the noise level. This limit occurs when the outdoor temperature exceeds 15 °C and limiting the compressors output to a maximum off 60 %. These criterias can be set individually
Dimensions (inside part) (W x D x H) – Integrated in Compact P | 550 x 300 x 1.100 mm |
Weight (inside part) | 55 kg |
Control | CTS 700 |
Dimensions (outside part) (W x D x H) | 962 x 542 x 1.301 mm |
Weight (outside part) | 125 kg |
Supply voltage (inside part) | 400/230V 2L+ N+PE, 50Hz |
PMAX (inside part) | 6,1 kW |
Fuse size (inside part) | 16 A |
Standby electricity consumption | 2,5 W |
Supplementary electrical heating | 2 x 3 kW |
Buffer tank(integrated) |
50 L |

AUTOMATION

Functional overview CTS 700 control panel
CLICK TO VIEW
Functional overview | +Standard -Accessories | |
3 levels | The control function is divided into 3 levels: User / Installer / Factory with various options at each level. | + |
Weekly plan | There is an option for you to set your own weekly programme. | + |
User option 1 | This allows you to override the operating mode in the main menu via an external potential-free contact or PIR sensor. | + |
User option 2 | This allows you to override the operating mode in the main menu via an external potential-free contact or PIR sensor. User option 2 has a higher priority than user option 1. | + |
User option 2 out | When user option 2 is used, at the same time an output signal is given. | + |
Alarms | The alarm list is featuring all alarms. | + |
Datalog | Opportunity for datalog. | |
Filter monitor | Filter monitor with timer (factory setting of 90 days). Adjustable to 30/90/180/360 days. | + |
100% Bypass | Bypassing the outdoor air reduces heat recovery, enabling the desired supply air temperature to be maintained spring, summer and autumn. | + |
Air quality | Allows you to choose whether to switch humidity sensors and/or CO2 sensors on and off. | +/- |
Humidity control | Allows you to set a higher or lower ventilation step in the case of high/low air humidity. | + |
CO2 control | Allows you to set a higher or lower ventilation step in the case of a high/low CO2-level. | – |
Air exchange | Allows you to select a low ventilation step in the case of low outside temperatures and air humidity. | + |
Night setback | A possibility to set back the ventilation and temperature a night. | + |
Defrost function | Temperature-based automatic function for defrosting the heat exchanger. | + |
Frostprotection | In case of failing heating system, the unit is turned off to avoid further cooling with a risk of the water heating coil frost bursting. | + |
Temperature control | Allows you to select the temperature sensor which will control the unit. • TExt External room temperature sensor • T3 EXHAUST (extract air) |
– + |
Air volume | Allows you to set the ventilation flow stepless from 20 to 100 %. In four steps. | + |
Summer/Winter operation | The unit automatically changes to summer or winter operation. | + |
Legionella control | It is possible to choose a weekday or a day during the month, where the sanitary hot water temperature reaches 65 °C, for example between 1 and 6 o´clock. | + |
Fire alarm | This allows you to connect fire-detecting thermostats, smoke detectors and other fire alarm contacts. In case of an alarm, smoke dampers are closed and the unit stops. | + |
Joint alarm | Outlet for joint alarm. | + |
Cooling | Via bypass or heat pump. The heat pump has a reversible circuit, which means that the units circuit is reversed and the unit cools, rather than heating, the supply air. It is possible to choose whether the unit is to run a higher or highest ventilation stage during cooling. Via a weekly plan night cooling can be set up. | + |
External heating element | • Temperature sensor T7 is an supply air sensor • Integrated frost protection for external water heating element • Motorised valve and circulation pump control unit |
– |
External electric heating element | • Temperature sensor T7 is an supply air sensor • Overheating protection |
– |
External network | It is possible to connect the unit to an external network. | + |
Reset | Allows you to restore the factory settings. | + |
Language | Option for setting the relevant language (Danish/German/English). | + |

18 Connection 1”
19 Flexihose 1”
20 Shut-off valve
21 P1 circulation pump 130 mm
23 Supplementary electrical heating 2 x 3 kW
24 Temperature sensor T18 (centralvarme)
25 Flexihose 10 mm
26 Automatic control vent
27 Expansion tank 8 litre
28 Manometer
29 Safety valve 2,5 bar
31 P2 circulation pump
33 Connection 3/4”
34 Connection 3/4”
37 Feed cock
39 Shut-off valve
43 3-way valve
44 Temperature sensor T21
45 Temperature sensor T22
50 Temperature sensor evaporator
52 Temperature sensor T16
53 Temperature sensor T17
ACCESSORIES